Industrial wastewater 4

Technical data "BIO-CLEAN" 4.100
Absorption surface in rotors: ca. 800 m2
RPM: 3.2 - 4.8
Recirculation system of the last biorotor, in addition to dosing and/or first compartment of the buffer tank (denitrification).
Very low biological load: 4.5 gr/m2/d
The produced bacteriological material is released from the gasket by means of a growing and detaching process. It then leaves the biorotor with the effluent into a post-precipitation tank.
3c. Precipitation tank.
In the post-precipitation tank, the bacteriological matter sinks to the bottom. A pump periodically removes the matter into the buffer tank where it undergoes the same decomposition process as the sediment that settles directly. Possible surface skims caused by floating residue is also drained into the buffer tank by means of a skimming system. The limpid effluent leaves the system via a "diving-partition” and over an indented rim to be evacuated.
Dimensions and loads of the precipitation tank:
Surface : 1.85 m2 - content 1.250 m3
Max. depth : 1.55 m - surface load 0.1 - 0.2 m2/h
 

4. Purification result.
The effluent will meet the evacuation requirements to the fullest, especially with the low B.O.D. 5 load of 4.5 gr./ m2/d.
If an in-depth nitrification and nitrogen elimination is required, the load can be reduced to 3 gr. B.O.D. 5 m2/d by lowering the design capacity P.U. by one third.
A maximum purification is definitely within reach due to the over dimensioning of the units and the low hydraulic load of about 5 m3/d.
The recirculation system offers more possibilities even, to obtain a perfect quality of effluent.
5. Soil pollution.
The alternative exists to dimension the "BIO-CLEAN" in such a way that whenever soil pollution is discovered ( caused by petrol, diesel etc.) a groundwater purification can be performed at the same time. A bio chemical process in a biological way.
Our units have been developed in close cooperation with experts in the field of water engineering. By using a special kind of steel, our units cannot rust through and don't need any coating. The plant can be used as a mobile unit.

Available standard types:

Type

steps

p.e.

m3 / h

surface

kW

dim.

Bio-Clean 4020

4

15 - 20

0,1

150 - 200

0,125

2,1 x 0,8 x 1

Bio-Clean 2050

2

50

0,31

400

0,37

2,8 x 1,7 x 1,75

Bio-Clean 3075

3

75

0,47

600

0,37

3,6 x 1,7 x 1,75

Bio-Clean 4100

4

100

0,625

800

0,37

4,3 x 1,7 x 1,75

Combi-Clean 2000

3

250

12

2000

1,1

4,7 x 2,1 x 2,2

Combi-Clean 3000

3

375

20

3000

1,1

4,7 x 3,1 x 2,9

Combi-Clean 4000

3

500

25

4000

2,2

4,7 x 3,1 x 2,9

Combi-Clean

4

625

4,7

5000

4

5,2 x 3,5 x 3

Combi-Clean 10000

5

1000

30

10000

7,5

7,0 x 3,6 x 3,5

P.E.= Population equivalent
Above figures are based upon the average European population standards i.e. 150 l. wastewater per p.e. with load of max. 60 gr. B.O.D / day.